Power Outages & Backup Power
The EIA reports that U.S. electricity customers averaged about 11 hours without power in 2024, nearly twice the decade average, with about 9 of those hours caused by major events such as hurricanes. Outside major events, interruptions routinely average about 2 hours a year. South Carolina customers averaged nearly 53 hours in 2024.
4 guides · newest update Oct 29, 2026 · how we research
Start here
- Step 1Generator Repair Cost 2026: What Repairs Really Cost, by PartGenerator repair cost in 2026: most US repairs $200-$600 (Modernize); battery $60-$150, carburetor $50-$300, transfer switch $500-$1,000, stator $250-$1,500 (Angi). Canada servicing C$150-$300/yr (HomeStars). Repair-or-replace math included.Updated Oct 29, 2026
- Step 2What Size Generator Do You Need? A Load Worksheet With Surge, Fuel and Connection RulesSize a generator from nameplates: running watts, starting surge, 120/240 V legs, fuel runtime for real outage hours, and the safe ways to connect it.Updated Oct 28, 2026
- Step 3Off-Grid Suburban Homes in 2026A realistic look at off-grid suburban homes in 2026, including winter sizing, permits, batteries, backup heat, and why most households should start with grid-tied resilience.Updated Jul 10, 2026
All topic guides
About this topic
Planning for the Hours Without Power
The EIA reports that U.S. electricity customers averaged about 11 hours without power in 2024, nearly twice the decade average, with about 9 of those hours caused by major events such as hurricanes. Outside major events, interruptions routinely average about 2 hours a year. South Carolina customers averaged nearly 53 hours in 2024.
Size for the Loads That Must Run
Backup power is a sizing problem before it is a shopping problem. The sizing worksheet in this hub starts from the loads that have to keep running (refrigeration, sump and well pumps, heating controls, medical devices), read their nameplates, and work out running watts, starting surge and the fuel or battery energy a realistic outage needs.
Safety Comes With the Equipment
CPSC reports that nearly 100 people in the U.S. die each year from carbon monoxide poisoning caused by portable generators, and its guidance is to run them outside only, at least 20 feet from the house. Connecting a generator to house wiring without a transfer switch can energize utility lines. The worksheet treats placement, connection and CO alarms as part of the sizing, not an afterthought.
Match the Plan to the Outage You Expect
A short outage and a multi-day outage need different equipment. Ready.gov's guidance is that a refrigerator keeps food cold for about four hours and a full freezer holds its temperature for about 48 hours, so refrigeration alone rarely needs power every hour. Pumps, heating controls and medical devices are different: they set the minimum running capacity and the fuel or battery energy a long outage requires. The worksheet turns that list into watts and gallons, and our battery critical-load sizing guide does the same in kilowatt-hours, so a portable generator, a standby unit and a battery can be compared on the same footing.
Use this hub alongside the standby generator cost guide, the transfer switch installation cost guide and the battery sizing guide above to choose a backup plan that fits your outage history.