Time-of-day and pilot rates
The tariff book sets out three alternatives to the flat rate, each with its own eligibility rules. The prices below exclude riders, which are added on top.
Time-of-Day
This optional rate is limited to homes with electric thermal storage or in-floor radiant heating with thermal storage, so it isn't open to everyone. The customer charge is $20.08 a month, the same as on the standard tariff.
| Period |
December to February |
March to November |
| 7 a.m. to 12 p.m. |
24.384 cents |
19.459 cents (7 a.m. to 11 p.m.) |
| 12 p.m. to 4 p.m. |
19.459 cents |
19.459 cents |
| 4 p.m. to 11 p.m. |
24.384 cents |
19.459 cents |
| 11 p.m. to 7 a.m. |
11.632 cents |
11.632 cents |
Weekends and statutory holidays are billed at the overnight price, which rises to 11.750 cents on January 1, 2027.
Here's how it works out for a storage-heat home using 2,000 kWh in a winter month, 1,100 kWh of it charged overnight and 900 kWh at the top daytime price of 24.384 cents. On Time-of-Day the energy costs 1,100 x 11.632 cents + 900 x 24.384 cents = $347.41. On the standard tariff it costs 2,000 x 18.324 cents = $366.48. The home saves about $19 that month (the customer charge is identical on both), and the saving grows as more of the load moves overnight.
Time-of-Use pilot (rate code 80)
The winter period runs from November 1 to March 31. Its peak hours, 7 to 11 a.m. and 5 to 9 p.m., cost 36.517 cents per kWh from November 1, 2026 and 38.281 cents from January 1, 2027. Off-peak power costs 18.324 cents, then 19.067 cents. Between April 1 and October 31 an interim energy charge of 18.324 cents applies, and a non-winter charge of 12.860 cents is set from April 1, 2027. The pilot pays off for homes that can move winter use out of the peak hours.
Critical Peak Pricing pilot (rate code 70)
Power used during a critical peak event costs 182.067 cents per kWh from November 1, 2026 and 191.990 cents from January 1, 2027. Every other hour costs 15.411 cents, then 15.956 cents. According to the tariff book, no critical peak events are scheduled while the interim charge applies. Only a household that can switch off almost everything at short notice should consider it.
How electric heat households are affected
Electric baseboards are common in Nova Scotia and heat pumps are spreading, so winter months like those in the bill table are ordinary here. At 19.128 cents, each kWh a heat pump avoids is worth a good deal. Say a heat pump delivers 2.5 units of heat per kWh, a figure we use for planning rather than one measured in any house. Moving 5,000 kWh of baseboard heat onto it would save about 3,000 kWh, or about $574 a year. Efficiency drops below freezing, as our cold-climate heat pump performance data shows.
A house that already has thermal storage should run its own numbers on the Time-of-Day tariff and check that the overnight price still works after the 2027 changes. And since many homes here still burn oil, compare fuels before you replace anything. Our winter heating cost comparison by fuel puts the cost per unit of heat side by side.
Ways to lower the bill
Start with the incentives. Provincial and federal programs change often, so read our Nova Scotia home energy rebates guide and confirm the amounts on each program's own page before you buy. Air sealing and insulation save the same 19.128 cents per kWh in any month, and insulation payback by climate shows how quickly that adds up. A thermostat schedule is worth a look too; see smart thermostat savings by region.
When you read the bill, note that the DSM rider pays for efficiency programs. Our bill reading guide goes through the other lines.