By EnergyBS Editorial Team | Updated November 23, 2026
A house with aluminum branch-circuit wiring is not a reason to walk away, but it needs a repair plan and an insurance answer before you remove conditions. The U.S. Consumer Product Safety Commission (CPSC) found that aluminum-wired homes built before 1972 were 55 times more likely than copper-wired homes to have an outlet connection overheat, and one Northern Virginia electrician priced a whole-home connector repair at $2,000 to $8,000 against $15,000 to $35,000 for a full rewire of a 2,000 to 4,000 square foot house.
Aluminum wiring facts a buyer can check
| Figure | Value | Source (checked November 23, 2026) |
|---|---|---|
| Outlet hazard finding | 55 times more likely for aluminum-wired homes built before 1972 | CPSC Publication 516 |
| Era of use | 1965 to the mid-1970s (CPSC); roughly 1965 to 1973 (InterNACHI); mid-1960s to late 1970s (Ontario regulator) | CPSC, InterNACHI, Electrical Safety Authority |
| Permanent repairs the CPSC accepts | Copper rewire, COPALUM crimp, AlumiConn where COPALUM is unavailable | CPSC Publication 516 |
| COPALUM cost per device | About $50 per outlet, switch or fixture | InterNACHI |
| Whole-home connector repair (Northern Virginia, USD) | $2,000 to $5,000 AlumiConn; $3,000 to $8,000 COPALUM | AJ Long Electric |
| Full rewire (Northern Virginia, USD) | $15,000 to $35,000 for 2,000 to 4,000 sq ft | AJ Long Electric |
Which houses have aluminum branch wiring, and which do not?
Houses built or expanded between about 1965 and the mid-1970s are the ones to check. The CPSC explains that a copper shortage in the mid-1960s pushed builders to move aluminum from the few large circuits, such as dryers and ranges, onto general-purpose 15 and 20 amp circuits. It says homes built before 1965 are unlikely to have aluminum branch wiring, while cable installed from 1965 to the mid-1970s in new homes, additions and rewired circuits may contain it. InterNACHI narrows the peak to roughly 1965 to 1973, and Ontario's Electrical Safety Authority (ESA) widens the window to the mid-1960s through the late 1970s. Treat the era as a screen, not a cutoff: an addition from 1971 on a 1950 house can carry aluminum while the original rooms do not.
You can often confirm it yourself in an unfinished basement, attic or garage. Nearly all of it was plastic-sheathed NM cable (often called Romex), and the jacket is printed or embossed every few feet. The CPSC says aluminum cable shows "Al" or "Aluminum", and that aluminum conductors are sized No. 12 for 20 amp and No. 10 for 15 amp circuits, a size larger than copper. InterNACHI adds that terminals marked CO/ALR indicate devices made for aluminum, and that shining a flashlight along the jacket helps with faded markings.
Some aluminum you find will not be the problem the CPSC studied. If the jacket says "CU-clad" or "Copper-clad", the cable is copper-coated aluminum, and Publication 516 says its repair advice does not apply. The same goes for service entrance cable and the heavy circuits for dryers and ranges, so aluminum on the service drop of a 1990s house is a separate question from aluminum branch circuits. And in a house with a copper original and an aluminum addition, only the aluminum circuits need the repair, which can cut the quote sharply.