By EnergyBS Editorial Team | Updated November 23, 2026
A typical 3-ton central air conditioner draws about 3 kW while it runs and uses roughly 1,300 to 5,000 kWh over a cooling season, depending on how many hours it works. At the US average residential electricity price of 18.16 cents per kWh (EIA, August 2026) that is about 56 cents an hour and $230 to $910 a season. Climate sets most of the range, more than the machine does.
What a central AC draws
| Figure | Value | Source (checked November 23, 2026) |
|---|---|---|
| Federal minimum, North | 13.4 SEER2 (split and package) | AHRI regulatory page |
| Federal minimum, Southeast and Southwest, split under 45,000 Btu/h | 14.3 SEER2 | AHRI regulatory page |
| Southwest split under 45,000 Btu/h, EER2 floor | 11.7 EER2 | AHRI regulatory page |
| US average residential price, August 2026 | 18.16 cents per kWh | EIA Electric Power Monthly, Table 5.6.A |
| Air conditioning share of household electricity, 2020 | 19 percent | EIA, electricity use in homes |
| Smart thermostat saving on heating and cooling | More than 8 percent, about $50 a year | ENERGY STAR |
How many kilowatts does a central air conditioner draw?
A central air conditioner draws its capacity in Btu per hour divided by its EER2, in watts, while the compressor runs at full speed. One ton of cooling is 12,000 Btu/h, so a 3-ton unit is 36,000 Btu/h. At the Air-Conditioning, Heating, and Refrigeration Institute's southwestern minimum of 11.7 EER2 for a split system under 45,000 Btu/h, the draw is 36,000 / 11.7 = 3,077 watts, or about 3.1 kW. EER2 rates efficiency at one hot-day test point, while SEER2 averages performance across a season, so the two numbers answer different questions.
The table shows full-load draw in kW. The 9.8, 10.6 and 11.7 EER2 columns are minimums from the AHRI regional standards: 9.8 is the Southwest floor for units at or above 15.2 SEER2, 10.6 the Southwest single-package floor and 11.7 the Southwest split floor. The 13 EER2 column is an illustration of a better unit.
| Size | Btu per hour | 9.8 EER2 | 10.6 EER2 | 11.7 EER2 | 13 EER2 (illustration) |
|---|---|---|---|---|---|
| 2 ton | 24,000 | 2.45 kW | 2.26 kW | 2.05 kW | 1.85 kW |
| 3 ton | 36,000 | 3.67 kW | 3.40 kW | 3.08 kW | 2.77 kW |
| 4 ton | 48,000 | 4.90 kW | 4.53 kW | 4.10 kW | 3.69 kW |
| 5 ton | 60,000 | 6.12 kW | 5.66 kW | 5.13 kW | 4.62 kW |
A real house bends these numbers. A variable-speed unit draws less than the full-load figure for most of the day, and a hot afternoon pushes real draw above the rating point. The indoor blower and outdoor fan are part of the system but vary by installer, so treat the table as a planning figure, not a nameplate. For how SEER2, EER2 and HSPF2 relate, see our SEER2 and HSPF2 explainer.