By EnergyBS Editorial Team | Updated November 23, 2026
A standard electric ENERGY STAR clothes dryer uses about 2.15 kWh per load. Over the 283 loads in the federal test year that comes to 607 kWh, and at the US average residential electricity price of 18.16 cents per kWh (EIA, August 2026) each load costs about 39 cents. Drying five loads a week runs roughly $102 a year, and a heat pump dryer halves that to about $51.
Dryer energy at a glance
| Figure | Value | Source (checked November 23, 2026) |
|---|---|---|
| Average certified standard electric vented dryer | 607 kWh per year, combined energy factor 3.94 | ENERGY STAR certified product data |
| Federal minimum combined energy factor, standard electric | 3.73 pounds per kWh | 10 CFR 430.32(h) on eCFR |
| ENERGY STAR minimum, standard electric | 3.93 pounds per kWh | ENERGY STAR key product criteria |
| Cycles and test load in the federal test | 283 cycles a year, 8.45 pound load | Federal Register, October 8, 2021 |
| Average certified heat pump dryer (standard size) | 308 kWh per year | ENERGY STAR certified product data |
| US average residential price, August 2026 | 18.16 cents per kWh | EIA Electric Power Monthly, Table 5.6.A |
How much electricity does one load use?
An efficient standard electric dryer uses about 2.15 kWh to dry a full 8.45 pound test load, and a dryer at the federal minimum uses about 2.27 kWh. Both come from one piece of arithmetic. A dryer's efficiency rating is its combined energy factor (CEF), the pounds of clothes dried per kWh, so the test load divided by the CEF gives kWh per load:
- Federal minimum, standard electric: 8.45 / 3.73 = 2.27 kWh per load (10 CFR 430.32).
- ENERGY STAR minimum: 8.45 / 3.93 = 2.15 kWh per load.
- Average certified standard electric dryer, CEF 3.94: 8.45 / 3.94 = 2.14 kWh per load.
The Department of Energy's test procedure, described in its October 2021 Federal Register notice, supplies both the 8.45 pound load and the 283-cycle year. Multiply 2.15 kWh by 283 cycles and you get 608 kWh, which matches the 607 kWh ENERGY STAR lists for certified standard electric vented models. The test load is a laboratory load, so real cycles run higher or lower depending on how wet the clothes are and how full the drum is.
The same ENERGY STAR data gives those 367 vented models an average test cycle of 66.5 minutes. Divide 2.15 kWh by 1.11 hours and the average draw is about 1.9 kW. The heating element pulls more than that while it is on and stops when the thermostat is satisfied, so the cycle average is the number to use for cost.
Here is the cost of one load at three prices, using 2.15 kWh:
| Price | Source | Per load, standard electric | Per load, heat pump (1.09 kWh) |
|---|---|---|---|
| 14.63 cents | Washington, August 2026 | $0.31 | $0.16 |
| 18.16 cents | US average, August 2026 | $0.39 | $0.20 |
| 29.75 cents | California, August 2026 | $0.64 | $0.32 |
The prices come from the EIA Electric Power Monthly table. The heat pump column is the 308 kWh average divided by 283 loads.