EnergyBS
    Appliances

    How Much Electricity Does a Clothes Dryer Use? kWh per Load and per Year

    A standard electric ENERGY STAR clothes dryer uses about 2.15 kWh per load, or about 607 kWh a year on the federal test of 283 loads. At the US average residential price of 18.16 cents per kWh (EIA, August 2026) that is about 39 cents a load. Certified heat pump dryers average about 308 kWh a year, roughly half as much.

    EnergyBS Editorial Team7 sources14 min read

    Direct Answer

    A standard electric ENERGY STAR clothes dryer uses about 2.15 kWh per load, or about 607 kWh a year on the federal test of 283 loads. At the US average residential price of 18.16 cents per kWh (EIA, August 2026) that is about 39 cents a load. Certified heat pump dryers average...

    Quick Checks

    • 1A standard electric ENERGY STAR dryer uses about 2.15 kWh per load: the 8.45 pound federal test load divided by its combined energy factor of 3.93 pounds per kWh.
    • 2At the US average residential price of 18.16 cents per kWh (EIA, August 2026), one load costs about 39 cents and five loads a week costs about $102 a year. At California's 29.75 cents, five loads a week is about $166.
    • 3The federal test assumes 283 loads a year, which gives 607 kWh for the average certified electric dryer. Your own bill follows your loads per week, so multiply them by about 2.15 kWh.
    • 4Certified heat pump dryers average about 308 kWh a year (208 to 460 kWh), roughly half of a conventional electric dryer.
    • 5Over-drying costs real money: ENERGY STAR says an extra 15 minutes per load can cost up to $34 a year. Use the moisture sensor cycle and clean the lint filter every load.
    • 6Most plug-in meters are 120 volts and will not fit a 240-volt dryer outlet. To measure your own dryer, use a 240-volt rated meter, a clamp meter or your utility's interval data.
    On this page(10 sections)Show
    1. Dryer energy at a glance
    2. How much electricity does one load use?
    3. How much does each dryer type use in a year?
    4. What does a dryer cost to run at your number of loads?
    5. How can you check what your own dryer uses?
    6. Why do some dryers cost more per load?
    7. Is a heat pump dryer or a new dryer worth the money?
    8. Which assumptions mislead dryer cost estimates?
    9. Frequently Asked Questions
    10. Related Reading

    By EnergyBS Editorial Team | Updated November 23, 2026

    A standard electric ENERGY STAR clothes dryer uses about 2.15 kWh per load. Over the 283 loads in the federal test year that comes to 607 kWh, and at the US average residential electricity price of 18.16 cents per kWh (EIA, August 2026) each load costs about 39 cents. Drying five loads a week runs roughly $102 a year, and a heat pump dryer halves that to about $51.

    Dryer energy at a glance

    Figure Value Source (checked November 23, 2026)
    Average certified standard electric vented dryer 607 kWh per year, combined energy factor 3.94 ENERGY STAR certified product data
    Federal minimum combined energy factor, standard electric 3.73 pounds per kWh 10 CFR 430.32(h) on eCFR
    ENERGY STAR minimum, standard electric 3.93 pounds per kWh ENERGY STAR key product criteria
    Cycles and test load in the federal test 283 cycles a year, 8.45 pound load Federal Register, October 8, 2021
    Average certified heat pump dryer (standard size) 308 kWh per year ENERGY STAR certified product data
    US average residential price, August 2026 18.16 cents per kWh EIA Electric Power Monthly, Table 5.6.A

    How much electricity does one load use?

    An efficient standard electric dryer uses about 2.15 kWh to dry a full 8.45 pound test load, and a dryer at the federal minimum uses about 2.27 kWh. Both come from one piece of arithmetic. A dryer's efficiency rating is its combined energy factor (CEF), the pounds of clothes dried per kWh, so the test load divided by the CEF gives kWh per load:

    • Federal minimum, standard electric: 8.45 / 3.73 = 2.27 kWh per load (10 CFR 430.32).
    • ENERGY STAR minimum: 8.45 / 3.93 = 2.15 kWh per load.
    • Average certified standard electric dryer, CEF 3.94: 8.45 / 3.94 = 2.14 kWh per load.

    The Department of Energy's test procedure, described in its October 2021 Federal Register notice, supplies both the 8.45 pound load and the 283-cycle year. Multiply 2.15 kWh by 283 cycles and you get 608 kWh, which matches the 607 kWh ENERGY STAR lists for certified standard electric vented models. The test load is a laboratory load, so real cycles run higher or lower depending on how wet the clothes are and how full the drum is.

    The same ENERGY STAR data gives those 367 vented models an average test cycle of 66.5 minutes. Divide 2.15 kWh by 1.11 hours and the average draw is about 1.9 kW. The heating element pulls more than that while it is on and stops when the thermostat is satisfied, so the cycle average is the number to use for cost.

    Here is the cost of one load at three prices, using 2.15 kWh:

    Price Source Per load, standard electric Per load, heat pump (1.09 kWh)
    14.63 cents Washington, August 2026 $0.31 $0.16
    18.16 cents US average, August 2026 $0.39 $0.20
    29.75 cents California, August 2026 $0.64 $0.32

    The prices come from the EIA Electric Power Monthly table. The heat pump column is the 308 kWh average divided by 283 loads.

    Advertisement

    How much does each dryer type use in a year?

    Annual use runs from about 130 kWh for a small plug-in unit to about 690 kWh for the worst full-size electric model, and the dryer type decides where you land. The table is from the ENERGY STAR certified product data queried on November 23, 2026. ENERGY STAR's estimate assumes the 283-cycle federal test year, so read each figure as a standard-load benchmark, not a forecast of your bill. Every row is a plain average across listed models.

    Dryer type Models listed Average combined energy factor Average kWh per year Range
    Electric standard vented (4.4 cu ft or larger) 367 3.94 607 531 to 687
    Electric standard ventless, heat pump class (CEF above 5) 39 8.48 308 208 to 460
    Electric compact ventless, 240 volt 61 3.70 259 122 to 317
    Electric compact vented, 240 volt 3 3.45 246 not applicable
    Electric compact, 120 volt 13 about 6.4 133 133

    Heat pump dryers use roughly half as much as vented ones, with a wide spread. ENERGY STAR says they use around 70 percent less energy than conventional dryers. The best certified models fit that claim (208 kWh is about 66 percent below 607), but the average does not (308 kWh is about 49 percent below). Our heat pump dryer vs vented dryer guide covers drying time, price and installation.

    Ventless does not automatically mean heat pump. In the ENERGY STAR data, 15 standard-size ventless models have a combined energy factor below 5 and average 582 kWh a year, close to a vented dryer, while the 39 above 5 average 308 kWh. A CEF above 5 marks a heat pump class machine.

    Compact units look efficient mostly because they are small. They dry smaller loads, so the kWh per pound is not much better. Gas dryers are left out of the table: they burn gas for heat and use a little electricity for the drum and controls, and ENERGY STAR's listing for gas models mixes the two into one figure.

    The standards will tighten. From March 1, 2028, new federal standards under test appendix D2 apply (3.93 for standard electric, per 10 CFR 430.32(h)). That test also assumes 236 cycles a year instead of 283, so published kWh per year for new models will drop on paper even if the machine is unchanged.

    What does a dryer cost to run at your number of loads?

    Your cost is loads per year times kWh per load times price, and most households dry more or fewer than 283 loads. Use 2.15 kWh per load for a standard electric ENERGY STAR dryer and 1.09 kWh for a typical certified heat pump dryer.

    Take five loads a week: 5 x 52 = 260 loads. A standard electric dryer uses 260 x 2.15 = 559 kWh, which at 0.1816 is about $102. A heat pump dryer uses 260 x 1.09 = 283 kWh, or about $51.

    Loads per week Loads per year Standard electric kWh Cost at 18.16 cents Cost at 29.75 cents Heat pump kWh Heat pump at 18.16 cents Heat pump at 29.75 cents
    3 156 335 $61 $100 170 $31 $51
    5 260 559 $102 $166 283 $51 $84
    8 416 894 $162 $266 453 $82 $135
    10 520 1,118 $203 $333 567 $103 $169

    Every row is an illustration at the stated loads per week and the benchmark kWh per load. Measure your own load size and drying time for a closer number. On a time-of-use rate, ENERGY STAR suggests the delayed-start feature, and our time-of-use rates strategy guide shows what an off-peak window is worth.

    How can you check what your own dryer uses?

    Use a meter rated for 240 volts, a clamp-on meter at the dryer circuit, or your utility's interval data from a smart meter. Most inexpensive plug-in watt meters are built for 120 volt outlets and will not take a dryer plug, so a standard one is the wrong tool here. With a 240-volt capable meter, run a normal load and read the kWh. Then run five different loads and average them, since a towel load and a shirt load are not alike.

    Nameplate math gives a ceiling, not an average. The formula is watts x hours / 1000 = kWh, with watts taken as volts x amps from the label. Say the label reads 240 volts and 24 amps. That is 5,760 watts, so a full hour of continuous heating would be 5.76 kWh. The thermostat cycles the element, though, and the average over the test cycle is about 1.9 kW, which is why a 60 minute cycle uses about 2 kWh rather than 5.8. Use the label to check your breaker and wire size, and a meter to learn what the machine actually draws.

    A free third method: read the whole-house meter before and after one load with everything else off. It is crude, but it will catch a dryer using far more than 2 to 3 kWh a load.

    Why do some dryers cost more per load?

    Longer cycles are the main cause, and the cause behind longer cycles is usually airflow, wetness or settings. Over-drying comes first. ENERGY STAR says a dryer running an extra 15 minutes per load can cost up to $34 a year. As a cross-check, 15 minutes at the 1.9 kW cycle average is about 0.48 kWh a load, times 283 loads is about 137 kWh, or about $25 at 18.16 cents. The moisture sensor setting beats a timed cycle.

    Airflow comes second. ENERGY STAR says cleaning the lint risk before each load can save up to $34 a year, and a long or crushed vent run has the same effect (see our dryer vent routing and length guide). Dryer sheets leave residue on the filter that cuts airflow, so ENERGY STAR recommends scrubbing the filter monthly with a toothbrush if you use them.

    Wetness and load mix are the rest. Anything that leaves clothes wetter coming out of the washer adds drying minutes, and a machine that already needs two cycles is showing a symptom, covered in our dryer takes two cycles diagnostic. Towels dried with shirts mean the light items over-dry while the towels finish. And ENERGY STAR notes that drying one towel for 30 minutes costs about as much as drying a full load for the same time.

    Is a heat pump dryer or a new dryer worth the money?

    A heat pump dryer pays back when the yearly kWh saved times your price, over the years you keep it, exceeds the extra purchase price. In formula form, payback in years = extra price / ((old kWh - new kWh) x price per kWh).

    Suppose a heat pump model costs $600 more than a standard vented one, and it replaces a vented dryer averaging 607 kWh a year with one averaging 308. Both the price gap and the swap are illustrations. The saving is 299 kWh a year.

    • At 18.16 cents: 299 x 0.1816 = about $54 a year, so $600 / $54 is about 11 years.
    • At California's 29.75 cents: 299 x 0.2975 = about $89 a year, so about 6.7 years.
    • At Washington's 14.63 cents: 299 x 0.1463 = about $44 a year, so about 13.7 years.

    Moving up within the same type is a smaller prize. Going from the federal minimum (2.27 kWh a load) to the ENERGY STAR level (2.15 kWh) saves about 0.12 kWh a load, or about 2 cents at 18.16 cents. ENERGY STAR itself puts the lifetime saving of a certified electric dryer at about $210, which is no reason to replace a working machine. If the dryer is already failing, weigh the repair against replacement with our dryer repair cost guide, and use the life-cycle cost guide to add price and running cost together.

    Advertisement

    Which assumptions mislead dryer cost estimates?

    Dryer estimates mislead mostly when a peak rating is treated as an average, or a test assumption as your habit. Multiplying the nameplate by the cycle length counts the element as on for the whole cycle, and it is not. Using 283 loads for your household is another slip, because that is a test assumption: a couple might do two or three loads a week and a family of five might do ten.

    Mixing heat pump and vented numbers causes trouble too. Standard ventless models in the ENERGY STAR data average a 73 minute test cycle against 66 minutes for vented, yet heat pump models use far less energy in that time, so judge a dryer in kWh, not minutes. Gas dryer figures are no help either, since ENERGY STAR's data for gas models blends gas and electricity.

    The vent and the washer belong in the estimate as well. A long or kinked vent run adds minutes to every cycle. Spin speed and load size decide how wet the clothes are when they reach the dryer, so the cheapest dryer saving can be a better wash.

    Frequently Asked Questions

    How many kWh does a dryer use per hour?

    An electric dryer averages about 1.9 kWh per hour across a normal cycle, based on 2.15 kWh over the 66.5 minute test cycle in the ENERGY STAR data. The element draws more while it heats, up to the voltage and amperage on the nameplate, but it cycles on and off, so nameplate watts times hours overstates use.

    How much does it cost to run a dryer for one load?

    About 39 cents for a standard electric ENERGY STAR model at the US average of 18.16 cents per kWh, 64 cents at California's 29.75 cents, and 31 cents at Washington's 14.63 cents. A heat pump dryer costs about half that per load.

    Is a gas dryer cheaper than an electric dryer?

    Often, where gas costs less than electricity per unit of heat, because gas supplies the heat directly. No gas cost figure is given here, because ENERGY STAR lists gas models with a combined gas and electric number rather than an electricity-only one. Compare your own gas and electricity prices, and see our washer and dryer installation cost guide for the cost of running a gas line.

    Do dryers use a lot of electricity when idle?

    Idle draw is not in the ENERGY STAR kWh figures on this page, so your own meter is the best check. Leave a 240-volt capable meter on the dryer for a week without running it and read the kWh. Anything above a fraction of one kWh over the week is worth tracing to a display or a connected feature.

    How long should a load take in an efficient dryer?

    The ENERGY STAR key product criteria cap the test cycle at 80 minutes, and certified vented electric models in the data average about 66 minutes for the test load. If your normal cycle runs far longer, look for a lint, vent or sensor problem before blaming the machine.

    Can a ventless dryer run on a regular outlet?

    Some compact models run on a 120-volt outlet, and they appear in the ENERGY STAR data at about 133 kWh a year. For any other model, check the manual for its circuit needs before you buy. If a new circuit is required, our electrical panel upgrade cost guide explains what to expect.

    What to Read Next

    Heat Pump Dryer vs Vented Dryer 2026Use this next to compare the cost, incentive, installation, or operating-risk angle before you make a home energy decision.

    Sources and Verification

    Editorial Review

    EnergyBS Editorial Team

    EnergyBS publishes practical homeowner guides. Important program, product, and cost claims should be checked against the linked source and local project documents before you commit to work.

    Read our editorial policy and methodology, or report an error.

    Important: Educational Purposes OnlyThe guides, tools, cost estimates, and ROI calculators provided on EnergyBS.com are for informational and educational purposes only. They do not constitute certified financial, tax, or professional engineering advice. Energy costs, government rebates, and installation fees vary significantly by location and are subject to change. Always consult with certified local professionals before undertaking home energy projects or making financial commitments.