    Minimum Heat Requirements for Rentals in Six Places

    A landlord who supplies heat must hold at least 68°F in daytime hours in New York City, Chicago, Massachusetts and Washington, DC, with night minimums of 62°F, 66°F, 64°F and 65°F. In Ontario the provincial floor is 20°C from September 1 to June 15 and Toronto's bylaw sets 21°C from October 1 to May 15. Seasons differ by city, from September 15 to June 1 in Chicago to October 1 to May 1 in DC, and so do the penalties and the office you call.

    EnergyBS Editorial Team8 sources11 min read

    Direct Answer

    A landlord who supplies heat must hold at least 68°F in daytime hours in New York City, Chicago, Massachusetts and Washington, DC, with night minimums of 62°F, 66°F, 64°F and 65°F. In Ontario the provincial floor is 20°C from September 1 to June 15 and Toronto's bylaw sets 21°...

    Quick Checks

    • 1New York City owners must keep 68°F from 6 a.m. to 10 p.m. whenever it is below 55°F outside, and 62°F from 10 p.m. to 6 a.m. regardless of the weather, from October 1 to May 31 (NYC HPD).
    • 2Chicago's heat ordinance runs September 15 to June 1 at 68°F by day and 66°F at night, and portable space heaters do not count toward the requirement.
    • 3In Massachusetts the standard is 68°F from 7:00 a.m. to 11:00 p.m. and 64°F overnight, measured five feet above the floor on a wall more than five feet from an exterior wall (105 CMR 410.180).
    • 4Washington, DC sets 68°F by day and 65°F overnight from October 1 to May 1. Report problems to the Department of Buildings at (202) 671-3500 or on its online housing form.
    • 5In Ontario a landlord who provides heat must keep 20°C from September 1 to June 15, and Toronto's bylaw is stricter at 21°C from October 1 to May 15.
    • 6Keep a dated log with thermometer readings and copies of every written request. The Landlord and Tenant Board lists such records as evidence, and a city inspector will want them too.
    On this page(9 sections)Show
    1. The rules side by side
    2. When does the heating season start and stop?
    3. How is the temperature measured?
    4. What counts as heat?
    5. What can a tenant do about a cold apartment?
    6. Where renters get stuck
    7. Warmer homes cost money, whoever pays
    8. Frequently Asked Questions
    9. Related Reading

    By EnergyBS Editorial Team | Updated November 23, 2026

    If your landlord supplies the heat, the law in New York City, Chicago, Massachusetts and Washington, DC sets a daytime floor of 68°F, and in Ontario the floor is 20°C (68°F) provincially and 21°C (about 70°F) in Toronto. The night minimum is lower: 62°F in New York, 66°F in Chicago, 64°F in Massachusetts and 65°F in DC. What changes from place to place is the calendar, the hours, the way a building counts as "heated" and the office that takes your call.

    The rules side by side

    Place Season Daytime minimum Night minimum Rule and source
    New York City October 1 to May 31 68°F, 6 a.m. to 10 p.m., when it is below 55°F outside 62°F, 10 p.m. to 6 a.m., any weather Housing Preservation and Development, heat and hot water page
    Chicago September 15 to June 1 68°F, 8:30 a.m. to 10:30 p.m. 66°F, 10:30 p.m. to 8:30 a.m. Municipal Code 14X-8-803, Department of Buildings
    Massachusetts September 15 to May 31 68°F, 7:00 a.m. to 11:00 p.m. 64°F, 11:01 p.m. to 6:59 a.m. State Sanitary Code, 105 CMR 410.180
    Washington, DC October 1 to May 1 68°F, 6:30 a.m. to 11:00 p.m. 65°F, 11:00 p.m. to 6:30 a.m. Housing code, per the Attorney General and the Department of Buildings
    Toronto October 1 to May 15 21°C, set for all hours on the City's page Not set separately Heating Bylaw, City of Toronto
    Ontario September 1 to June 15 20°C, set for all hours Not set separately Provincial maintenance standards, Landlord and Tenant Board brochure, last updated 2018

    These were all checked November 23, 2026. Cities adjust dates and rename bylaws, so confirm the current text with the office that enforces yours before you act on it.

    Advertisement

    When does the heating season start and stop?

    On the calendar each place sets, and the calendars do not line up. Chicago starts first, on September 15, and runs to June 1. Massachusetts also starts September 15 but ends May 31, and the regulation lets a local board of health shorten the season: it may end it no earlier than May 15 or start it no later than September 30, and it must post notice. New York City and DC both start October 1, but DC stops May 1 and New York May 31.

    Toronto is the most detailed. The City says the Heating Bylaw requires 21°C from October 1 to May 15 when the owner provides heat. The City adds that between September 15 and October 15, and again from May 1 to June 1, an owner may turn the heat down or off if the building holds 21°C without it. In DC, two-pipe or slow-transition systems that cannot switch between heating and cooling quickly must supply heat starting no later than October 15 and ending no earlier than May 1.

    Ontario's provincial floor is the widest window of the six, September 1 to June 15, but it only applies where a landlord provides heat. The Landlord and Tenant Board adds that some municipal standards may be higher, which is the case in Toronto, so a Toronto tenant follows the Toronto bylaw.

    How is the temperature measured?

    Only Massachusetts spells it out. The regulation measures heat five feet above the floor on a wall more than five feet from an exterior wall. That excludes a reading next to a cold window, and it also excludes a reading taken in the middle of the floor near a radiator. The same section requires heat in every habitable room and every room containing a toilet, shower or bathtub, and it caps the temperature the system may produce at 78°F in any room.

    Chicago says heat must be provided in habitable spaces, toilet rooms and bathrooms, and that closets, hallways, storage areas and utility rooms have no minimum. DC's rule covers habitable rooms and bathrooms, and its Attorney General's alert adds toilet rooms. New York and Toronto publish the number but not a measuring method on the pages cited here, so use a basic thermometer placed in the middle of the room, away from windows and radiators, and write down the time.

    What counts as heat?

    In Chicago, a lot does not. The ordinance lists cooking appliances, water heating equipment and portable space heaters as sources that cannot be used to meet the minimums, and fireplaces are excluded too. Any permanent system the Chicago Mechanical Code recognizes qualifies: steam or hot water radiators, other hydronic heat, warm-air furnaces and heat pumps. A landlord who points a tenant to a plug-in heater has not met the ordinance. Our page on what a space heater costs to run shows what that substitute costs you.

    For buildings where tenants control their own heat, Chicago puts the equipment on the owner: it must be capable of maintaining 68°F under expected winter weather, in good working order, in a building whose windows, doors and walls keep the heat in. The tenant may be required to pay the gas or electric bill. Toronto draws the same line the other way, since its 21°C minimum applies when heat is provided at the owner's expense.

    What can a tenant do about a cold apartment?

    Start with the landlord in writing, and keep every message. The Landlord and Tenant Board suggests a log of dates and times of conversations, photographs, and copies of written correspondence, and Toronto's page asks tenants to request repairs in writing first. A thermometer log with dated readings, taken at the hours the rules cover, is the evidence that turns a complaint into a violation.

    Then call the city.

    • New York City: call 311 or use 311 Online. Complaints may be anonymous, in which case an inspector picks an apartment at random. Civil penalties run $250 to $500 per day for an initial heat violation and $500 to $1,000 per day for later ones, and HPD charges an owner $200 for each inspection after the first two heat violations in a season. If HPD's Emergency Repair Program restores heat, the owner is billed when indoor temperatures fall below 64°F by day or 58°F at night.
    • Chicago: file with 311, and the Department of Buildings inspects. Fines run $500 to $1,000 per day per violation, and the City says the reason heat is missing does not matter.
    • Washington, DC: submit the housing form on the Department of Buildings site or call (202) 671-3500.
    • Toronto: call 311 or file online as a property standards request. Landlords must answer urgent vital-service requests within 24 hours and others within seven days, and RentSafeTO apartment buildings of three or more storeys and 10 or more units carry a 24-hour deadline for urgent issues such as heat.
    • Ontario: the municipality can enforce its property standards bylaw, or the provincial maintenance standards where no bylaw exists. Separately, a tenant can file a Form T6 with the Landlord and Tenant Board.
    • Massachusetts: the regulation fixes the minimums and gives the local board of health authority over the season, so the local board is the place to ask how it applies. The regulation text names no state complaint office.

    The Ontario brochure is blunt on one point. Tenants should not withhold rent, even when maintenance is poor, because a landlord can apply to evict for unpaid rent. A tenant who files a T6 may ask the Board to allow payment of rent to the Board until the application is decided, and the Board decides whether to grant it. Remedies the Board can order include a rent abatement, repair orders by a deadline, and reimbursement of reasonable expenses.

    Where renters get stuck

    The most common surprise is the daytime trigger in New York. The 68°F minimum applies from 6 a.m. to 10 p.m. only when the outside temperature is below 55°F, so a 66°F apartment on a 58°F afternoon is not a daytime violation, while the 62°F night minimum applies in any weather.

    Another is the building-type exception. Chicago's two-pipe buildings, which switch a single system between heating and cooling, get a looser rule at the edges of the season, 64°F at all hours from September 15 until the nights drop below 45°F or October 15 (whichever comes first), and again from the first day in May that the outdoor temperature passes 75°F. DC has its own October 15 start for such systems.

    A third is hot water. New York's rule includes hot water at a constant 120°F all year, a separate duty that carries the same civil penalties. And in Toronto, where a unit has air conditioning the City requires the building to keep units at or below 26°C from June 1 to September 30, but where it does not, the City does not regulate summer temperatures.

    If your city is not in the table, look for its housing or property standards office, and search its code for "habitable" and "heat". The Massachusetts and Chicago regulations are good models for the questions to ask: season, hours, measurement point, who controls the equipment.

    Warmer homes cost money, whoever pays

    A landlord who meets the minimum still hands you a house that is cold at the edges: floors, windows and the wall behind the bed. If you pay the heating bill, the winter heating costs by fuel page shows what a season costs, and what causes cold floors lists draft fixes a tenant can often do without permission, and the air sealing guide for older homes covers the next step up. LIHEAP helps eligible households with bills. If you rent today and plan to buy, ask the questions on our energy audit before buying a house page, because owning a house means the heat is your problem. The Home Buying hub collects the rest.

    Advertisement

    Frequently Asked Questions

    What is the legal minimum temperature for a rental?

    It depends on where you rent. Where a landlord supplies the heat, it is 68°F by day in New York City, Chicago, Massachusetts and DC, and 20°C provincially in Ontario. Toronto's bylaw is 21°C. Night minimums are 62°F, 66°F, 64°F and 65°F in the four U.S. places.

    Can a landlord stop heat in May?

    Only after the local season ends. In Toronto the 21°C requirement ends May 15, in DC May 1, in Chicago June 1, in Massachusetts May 31 unless the board of health set an earlier date, and in New York May 31. In Ontario the provincial standard runs to June 15.

    Do space heaters count?

    Not in Chicago. The ordinance bars portable space heaters, cooking appliances, water heaters and fireplaces from meeting the minimums. The other cities' pages cited here do not address space heaters, so a landlord who relies on one invites a complaint anyway.

    Should I stop paying rent if there is no heat?

    In Ontario, the Landlord and Tenant Board says no, because a landlord can apply to evict for unpaid rent. File a T6 application instead and ask the Board to let you pay rent into the Board. Elsewhere, ask a tenant legal clinic before withholding, as rules differ by place.

    Who pays for heat if I control the thermostat?

    It depends on the lease and the system. In Chicago, tenants with individual heating equipment may be required to pay the gas or electric bill, but the landlord must keep the equipment capable of 68°F and the building sealed against heat loss. Toronto's 21°C rule applies when heat is provided at the owner's expense.

    What to Read Next

    Winter Heating Costs 2026-27 by Fuel and Region: EIA's Forecast, DecodedUse this next to compare the cost, incentive, installation, or operating-risk angle before you make a home energy decision.

    Sources and Verification

    Editorial Review

    EnergyBS Editorial Team

    EnergyBS publishes practical homeowner guides. Important program, product, and cost claims should be checked against the linked source and local project documents before you commit to work.

    Read our editorial policy and methodology, or report an error.

    Important: Educational Purposes OnlyThe guides, tools, cost estimates, and ROI calculators provided on EnergyBS.com are for informational and educational purposes only. They do not constitute certified financial, tax, or professional engineering advice. Energy costs, government rebates, and installation fees vary significantly by location and are subject to change. Always consult with certified local professionals before undertaking home energy projects or making financial commitments.