What does one day of filtering use?
It depends almost entirely on how fast the water moves. Take a 20,000-gallon pool and one full turnover a day, which means pumping the whole volume through the filter once. The arithmetic below uses average readings from ENERGY STAR's certified pump data for the 320 in-ground variable-speed models, and the efficiency range DOE found for single-speed pumps.
| Pump and speed |
Flow |
Power |
Time for one turnover |
Energy per turnover |
| Variable speed, low |
29.5 gpm |
109 W |
11.3 hours |
1.2 kWh |
| Variable speed, high |
63.0 gpm |
787 W |
5.3 hours |
4.2 kWh |
| Single speed, WEF 3.0 (illustration) |
Fixed |
Fixed |
Set by flow |
6.7 kWh |
For the first two rows, hours are 20,000 gallons divided by flow in gallons a minute, then divided by 60, and energy is hours times watts divided by 1,000. The single-speed row works the other way, because WEF is already flow per energy: 20,000 gallons is 20 kgal, and 20 divided by 3.0 is 6.7 kWh. The 3.0 is an illustration chosen inside the 1.81 to 3.73 range DOE reported for single-speed pumps, not a measurement of any one product.
Multiply by 365 and by your price per kWh to get a year. These are the totals for a pool filtered every day of the year at three prices from EIA's August 2026 table:
| Location |
Price |
Variable, low |
Variable, high |
Single, WEF 3.0 |
| Florida |
14.99 cents |
$67 |
$228 |
$365 |
| United States |
18.16 cents |
$82 |
$276 |
$442 |
| California |
29.75 cents |
$134 |
$452 |
$724 |
Annual kWh behind the table: about 450 for variable low, 1,520 for variable high and 2,433 for single speed. A pool used only five months a year costs less than half of these, and a pool in Florida or Arizona that runs all year costs the full amount. Heated pools and bigger ones scale up from here.
Why does slowing the pump save so much?
Pumps follow a steep rule: halve the speed and the power falls to one-eighth, according to ENERGY STAR. That is per hour. Half the speed also moves half the water, so filtering one pool volume takes twice as long, and the energy per turnover drops to about a quarter, not an eighth.
The ENERGY STAR data shows the same effect across real pumps. The average in-ground variable-speed model draws 787 W at 63.0 gpm and 109 W at 29.5 gpm. Flow falls by 53 percent and power by 86 percent. Per turnover that is 4.2 kWh against 1.2, a ratio of about 3.4 to 1. That is a little under the textbook four, because real pumps and plumbing do not follow the ideal rule exactly.
Filtering does not need much flow. ENERGY STAR says it takes about half the flow of running a pool cleaner, which is why a single-speed pump, set for the cleaner, wastes energy every hour it spends only filtering.
What does the 2021 federal rule require?
Dedicated-purpose pool pumps made from July 19, 2021 must meet a minimum weighted energy factor, set in 10 CFR 431.465(f). WEF is gallons moved per unit of electricity, in thousands of gallons per kWh, averaged across the speeds the pump is tested at. Higher is better.
For self-priming filter pumps, the type most in-ground pools use, from 0.711 to under 2.5 hydraulic horsepower, the rule is a formula:
WEF must be at least -2.30 x ln(hhp) + 6.59
Hydraulic horsepower is the useful power in the water, lower than the motor's nameplate horsepower. Plug in a few sizes and the minimum is 7.37 at 0.711 hhp, 6.59 at 1.0, 5.66 at 1.5, 5.00 at 2.0 and 4.48 at 2.5 (derived from the formula).
Now put DOE's pre-rule survey beside it. The Department of Energy found standard-size self-priming pumps ranging from 1.81 to 3.73 for single-speed, 3.41 to 5.45 for two-speed and 5.81 to 10.25 for variable-speed in its rulemaking. The best single-speed pump on the market, 3.73, falls short of the lowest requirement anywhere in the range, 4.48 (derived). So a new single-speed in-ground pump of this kind cannot meet the standard at any size, and the rule in practice means variable speed or, at the larger sizes, an efficient two-speed model. The rule does not say "variable speed" in those words. The effect comes from the arithmetic.
Three limits to that statement. The rule applies to pumps made after July 19, 2021, so a single-speed pump already in your equipment pad is legal to run and repair. Above-ground pumps and booster pumps have different, lower formulas (for non-self-priming pumps under 2.5 hhp, 2.87 minus 0.85 times ln(hhp) above 0.13 hhp, and 0.42 for boosters), and the ENERGY STAR data still lists three single-speed above-ground models averaging WEF 6.73 and ten single-speed booster pumps. Finally, WEF is a laboratory weighting. A pump pushing water through long runs of small pipe, a dirty filter and a heater will not reach its label figure.
The same section of the code adds two practical rules. Integral cartridge-filter and sand-filter pumps must be sold with a timer, and a pump with freeze protection must ship with it either off or set to run no more than an hour at no more than half speed when air temperature is 40 degrees F or below.