Monthly Cooling Cost by System Size and Climate
Cooling is simpler because SEER2 already folds in a season's mix of part-load and full-load operation. The inputs are equivalent full-load cooling hours in the peak month: the hours the unit would have to run flat out to remove that month's heat. The three climates are again illustrations with stated inputs: 350 hours for a hot-climate July (long days near the design temperature, as across much of Texas, Florida and Arizona), 200 hours for a warm-climate July, 90 hours for a mild one.
| System size |
Climate |
kWh, SEER2 16 |
kWh, SEER2 22 |
Cost at 18.16 cents, SEER2 16 |
Cost at 18.16 cents, SEER2 22 |
Cost at 15.91 cents (Texas), SEER2 16 |
| 1 ton |
Hot |
262 |
191 |
$48 |
$35 |
$42 |
| 1 ton |
Warm |
150 |
109 |
$27 |
$20 |
$24 |
| 1 ton |
Mild |
68 |
49 |
$12 |
$9 |
$11 |
| 1.5 ton |
Hot |
394 |
286 |
$72 |
$52 |
$63 |
| 1.5 ton |
Warm |
225 |
164 |
$41 |
$30 |
$36 |
| 2 ton |
Hot |
525 |
382 |
$95 |
$69 |
$84 |
| 2 ton |
Warm |
300 |
218 |
$54 |
$40 |
$48 |
| 2 ton |
Mild |
135 |
98 |
$25 |
$18 |
$21 |
| 3 ton |
Hot |
788 |
573 |
$143 |
$104 |
$125 |
| 3 ton |
Warm |
450 |
327 |
$82 |
$59 |
$72 |
The formula behind each kWh figure: capacity (Btu/h) × full-load hours ÷ (SEER2 × 1,000). For the 2-ton hot row at SEER2 16: 24,000 × 350 ÷ 16,000 = 525 kWh.
Cooling costs less than heating for the same size of system for two reasons: summer loads are smaller than winter loads in most of the US and Canada, and a heat pump moves heat across a much smaller temperature difference in July than in January, so its efficiency is higher.
Worked Heating Example: Adding a Mini-Split to an Oil-Heated Home in Maine
Illustration with stated inputs.
A Maine household heats with an oil boiler and used 700 gallons last winter. It installs a 2-ton cold-climate mini-split on the main floor and expects the mini-split to take over about 60% of the home's heat, leaving the boiler for upstairs bedrooms and the coldest nights.
Step 1: How much heat did the oil deliver? 700 gallons × 138,500 Btu per gallon × 85% boiler efficiency = 82.4 MMBtu delivered.
Step 2: How much does the mini-split take over? 60% × 82.4 = 49.4 MMBtu, which displaces 420 gallons of oil.
Step 3: kWh to deliver that heat. At a seasonal COP of 2.2: 49.4 × 1,000,000 ÷ 3,412 ÷ 2.2 = 6,587 kWh. At a seasonal COP of 2.6: 5,574 kWh.
Step 4: Cost. At Maine's August 2026 average of 32.11 cents: $2,115 at COP 2.2 or $1,790 at COP 2.6.
Step 5: Oil saved. 420 gallons at EIA's U.S. winter forecast of $5.26 a gallon = $2,209.
Result: a saving of $94 a year at COP 2.2 and $419 at COP 2.6. That is a real saving, but a much smaller one than a typical sales sheet promises, and it hinges on two numbers. Maine's electricity price is near the top of the country; at the Northeast's winter forecast average of 26.19 cents, the same heat costs $1,725 at COP 2.2 and the saving rises to $484. And COP: every 0.1 of seasonal COP is worth roughly $80 a year in this house.
The break-even COP against oil at these prices is the price per MMBtu from baseboard heat divided by the price per MMBtu from oil: $94.11 ÷ $44.68 = 2.11. Below a seasonal COP of 2.1, the Maine household would pay more to heat with the mini-split than with oil. The way to stay well above it is to let the mini-split carry the shoulder seasons and mild winter days, where its COP is often above 3, and to hand the coldest nights to the boiler. That is the dual-fuel logic covered in our heat pump backup heat guide.
Worked Cooling Example: A Texas Bedroom Wing
Illustration with stated inputs.
A Texas home adds a 1.5-ton two-head mini-split to a bedroom wing the central AC never cooled well. The heads are rated SEER2 20. In July the wing's cooling load equals 330 hours at full capacity.
kWh: 18,000 Btu/h × 330 h ÷ (20 × 1,000) = 297 kWh.
Cost: 297 × 15.91 cents = $47 for the month.
If the old arrangement was the central system running longer to drag the bedrooms down, the comparison is not with zero. Suppose the central AC, rated SEER2 14, had to remove the same 5.94 million Btu: 5,940,000 ÷ 14,000 = 424 kWh, or $67. The mini-split saves about $20 a month on that heat alone, and more if the central system can now be set a few degrees warmer for the rest of the house. If it cannot, and the mini-split is pure added comfort, the $47 is a new cost.
How Inverter Part-Load Operation Changes the Bill
A conventional single-stage air conditioner or heat pump is either at 100% or off. A mini-split's inverter compressor varies its speed; the Building America Solution Center notes that inverter compressors can ramp down to as little as 10% of rated capacity. That changes running cost in three ways.
It is usually more efficient at part load. At low speed the coils are oversized relative to the refrigerant flow, so the temperature lift the compressor has to create is smaller and the machine delivers more heat per kWh. Most of a heating season is part load. This is the main reason a mini-split's seasonal efficiency beats its full-speed rating.
It loses that advantage when it cycles. Once the zone's load drops below the compressor's minimum speed, the unit starts and stops like a single-stage machine, and each start wastes some energy. This is the cost of an oversized head in a small room. Our head placement guide shows how three small bedrooms on a multi-zone system can sit below that floor, and the organizing guide explains why one head per zone, rather than one per room, keeps more heads in their efficient range.
It punishes deep setbacks. With a furnace, setting the thermostat back overnight saves fuel because the furnace is equally efficient whenever it runs. With a mini-split, the morning recovery runs the compressor at full speed, where its COP is lowest, and on a cold morning that is also when the outdoor coil is most likely to frost. A modest setback of 2 to 3°F, or none, usually costs less than a 10°F setback followed by a hard recovery. Your own bill is the test: try a steady setpoint for two weeks and compare kWh per degree day.
How Defrost Changes the Bill
In heating mode the outdoor coil is colder than the outdoor air. When the air is near or below freezing and humid, moisture freezes on the coil, which blocks airflow and cuts capacity. The unit periodically reverses to melt it, briefly taking heat from the house to do so; the indoor fan usually stops so the room is not blown with cool air. You may see steam rising from the outdoor unit, which our defrost cycle explainer covers in detail.
Defrost energy is a real cost and it is not spread evenly. It is greatest in damp weather around freezing, not on the coldest dry days, because dry, very cold air carries little moisture to freeze. Two practical consequences for running cost:
- The outdoor unit needs space for meltwater to drain and must not sit where it refreezes into a block of ice around the base. A raised stand and a clear drain path are installation details that show up on the bill.
- A unit running in defrost far more often than its neighbours, or with ice that never fully clears, has a problem (low charge, a failed sensor, blocked airflow) and is burning electricity on it. That is a service call, not a running-cost assumption.
The cold column of the monthly heating table already uses a lower COP (2.1) partly to reflect defrost. If you are pricing a unit for a humid, cold coastal climate, use the model's NEEP-listed COP at 17°F as a sanity check rather than its HSPF2.
When a Mini-Split Beats Baseboard, Oil, Propane or Gas
The break-even seasonal COP against any fuel is: (cost of electric resistance heat per MMBtu) ÷ (cost of that fuel's delivered heat per MMBtu). Delivered heat per MMBtu for a fuel = price per unit ÷ (heat content per unit × appliance efficiency). Using EIA's 2026-27 winter forecast prices and EIA heat contents:
| Fuel, appliance |
Fuel price (EIA winter 2026-27 forecast) |
Delivered heat, $ per MMBtu |
Break-even mini-split COP, U.S. (18.23 cents) |
| Electric baseboard |
18.23 cents per kWh |
$53.43 |
1.0: any working mini-split wins |
| Heating oil, 85% |
$5.26 per gallon |
$44.68 |
1.20 |
| Propane, 80% |
$2.52 per gallon |
$34.44 |
1.55 |
| Propane, 95% |
$2.52 per gallon |
$29.01 |
1.84 |
| Natural gas, 80% |
$13.44 per Mcf |
$16.22 |
3.29 |
| Natural gas, 95% |
$13.44 per Mcf |
$13.66 |
3.91 |
Regional prices move these thresholds a lot:
| Region (EIA forecast prices) |
vs 95% gas |
vs 95% propane |
vs 85% oil |
| Northeast: power 26.19 cents, gas $16.12/Mcf, propane $3.28/gal, oil at the U.S. $5.26/gal |
4.69 |
2.03 |
1.72 |
| Midwest: power 16.87 cents, gas $10.38/Mcf, propane $2.04/gal |
4.69 |
2.11 |
n/a (oil priced for the U.S. only) |
| South: power 15.75 cents, gas $14.13/Mcf, propane $3.19/gal |
3.22 |
1.26 |
n/a (oil priced for the U.S. only) |
The decision rules that fall out of the two tables:
- Baseboard heat: always switch the load you can. Any functioning mini-split delivers more than one unit of heat per kWh, so every MMBtu moved from baseboards to a mini-split costs less. Natural Resources Canada's ENERGY STAR page puts the saving for certified ductless heat pumps at about 60% less energy than standard electric resistance heat. In the monthly table, the 2-ton cold-climate case is $250 against $526 for the same heat from baseboards.
- Oil: usually yes, but check your rate. At U.S. average prices the mini-split wins at a COP of 1.2, a figure even a basic unit beats until the very coldest hours. At Maine's August price the bar rises to about 2.1, as the worked example showed, and a cold-climate model matters.
- Propane: yes in most places for most of the season. The South's break-even of 1.26 is easy; the Northeast's 2.03 is met on most winter days by a cold-climate unit and missed on the coldest ones.
- Natural gas: usually no on running cost alone. A seasonal COP of 3.2 to 4.7 is needed, which only holds in the mildest climates. A mini-split can still make sense in a gas home for cooling, for a room the furnace heats badly, or as the shoulder-season heat source with the furnace as backup, but not as a bill-cutting replacement at current prices. Our heat pump vs gas furnace operating cost comparison works the full-house version.
These break-evens use energy prices only. Fixed monthly charges for a gas or propane account, tank rental and delivery minimums can tip the decision if a mini-split lets a household drop a fuel entirely, and a time-of-use or heat pump rate from your utility can lower the electricity price below the averages used here.
For the full set of regional winter forecasts behind these numbers, see our winter heating cost forecast by fuel.