2. Sizing: 10 kW vs. 14 kW vs. 18 kW vs. 22 kW vs. 26 kW
Residential air-cooled standby generators are sold in standard sizes, with 10, 14, 18, 22, and 26 kW the common steps in major product lines. Bigger is not automatically better - an oversized generator costs more to buy, burns more fuel during its weekly exercise cycle, and can "wet stack" (carbon fouling) if it runs far below its rated load for long periods. The right size comes from a load calculation, not a rule of thumb about square footage. Our generator sizing worksheet walks through that calculation from appliance nameplates, including starting surge and 120/240-volt leg balance.
Think about sizing in two tiers: essentials versus whole house.
- Essentials (managed load): refrigerator and freezer, furnace or boiler blower, well pump or sump pump, lights, internet and phone charging, a few outlets, and possibly one small air conditioner or a heat pump circuit. Most homes can cover essentials with a 10-14 kW unit when paired with load management.
- Whole house: everything above plus central air conditioning, electric range, electric dryer, electric water heater, and any shop or EV charging loads. Whole-house coverage for a typical 2,000-2,500 sq ft all-electric home usually points at 20-26 kW.
The table below sketches what each common size is typically used for. Treat this as a starting frame for the conversation with your installer, not a substitute for their load calculation.
| Generator size |
Typical role |
What it usually covers |
| 10 kW |
Essentials for a smaller home |
Fridge, furnace blower, sump/well pump, lights, electronics |
| 14 kW |
Essentials for an average home |
Above plus a few more circuits; the most common "essentials" pick |
| 18 kW |
Essentials plus some comfort loads |
Above plus one zone of AC or a heat pump with load shedding |
| 22 kW |
Near-whole-house |
Most homes' full load, possibly with managed shedding of one large appliance |
| 26 kW |
Whole house, larger homes |
Full coverage including central AC and electric appliances |
A word on air conditioning: a central AC's startup surge is the single hardest load in most homes. The compressor's inrush current can be several times its running current, and it is what pushes a 14 kW design to 18 or 22 kW. If your installer does a proper load calculation, they will measure or estimate this surge - if they skip it, that is a red flag.
The cheaper path: managed load
Instead of buying a 22 or 26 kW unit to cover everything at once, many homes install a 14-18 kW unit with smart load management. The transfer switch (or separate load-shed modules) watches the generator's output and temporarily drops non-essential circuits - the electric dryer, the second AC zone - when demand spikes. You get whole-house coverage with a smaller, cheaper, more fuel-efficient generator. The trade-off is behavioral: during an outage, the dryer may pause itself. For most families, that is an easy trade.
3. Transfer Switches: Whole-Home vs. Managed-Load
The automatic transfer switch (ATS) is the device that watches the utility feed, starts the generator when the power fails, and moves your house onto generator power - usually within about 10 seconds. It also moves you back when utility power returns. There are two design philosophies, and the choice affects both cost and generator size.
Whole-home transfer switch. The switch sits between your meter and your main panel and transfers the entire house. Simple to understand and operate - everything just works during an outage. The catch: your generator must be sized for your home's full simultaneous load (or you must be disciplined about what you run), which pushes you toward the larger, more expensive units.
Managed-load (load-shedding) transfer switch. The switch powers a sub-panel of essential circuits and uses load-shed modules or smart switching to drop heavy loads in priority order when the generator nears capacity. You buy a smaller generator, spend less on fuel, and still keep the important things running. The trade-off is complexity - the installer must design the priority list correctly, and you need to understand which circuits are protected.
Which should you choose? If your home is gas-heated (no electric furnace or large heat strips), has no well pump, and your "must-run" list is short, a managed-load design with a 14-18 kW unit is usually the value play. If you have electric heat, a well, a home office that must stay fully live, or family members with medical equipment, the simplicity of a whole-home switch with a properly sized unit is worth the premium. Tell your installer which camp you are in before they size the unit.
Because standby backup ties directly into your electrical panel, it is worth confirming your panel's capacity and condition before the project starts - an older or undersized panel can add meaningful cost. Our guide on electrical panel capacity for electrification explains what installers look for.
4. Fuel: Natural Gas vs. Propane
A standby generator has to eat something, and the choice is almost always natural gas or propane (diesel exists but is rare in residential standby). The right answer depends on what is already at your house.
Natural gas is the default when the house already has gas service. Advantages: no fuel storage on site, no refills to schedule, and the generator can run indefinitely as long as the gas utility holds pressure. The main cost question is whether your existing gas meter and service line can deliver enough volume. A 20+ kW generator is a large gas appliance - larger than most furnaces - and many homes need a meter upgrade. Your gas utility typically does the meter swap; the installer runs the line from the meter to the generator with its own regulator. Get the utility's answer in writing during quoting, because a "surprise" meter upgrade mid-project is expensive and delays everything.
Propane is the answer when there is no gas line - rural homes, or homes that heat with oil or electricity. You will need an on-site tank (above-ground or buried), sized so a long outage does not empty it. Tank sizing is a genuine design decision: a 20 kW unit at half load burns several gallons of propane per hour, so a standard 250-gallon tank (which holds about 200 usable gallons) covers roughly two to three days of continuous half-load runtime. A 500-gallon tank doubles that. Ask your installer to show the runtime math for your expected load, in hours, for the tank size they propose. The trade-off for propane is logistics: you own the fuel inventory, and during a widespread outage, delivery trucks may be delayed - so size the tank for the outage you are actually planning for, not the average one.
Neither fuel is "better" in the abstract. Natural gas wins on convenience where it exists; propane wins on availability where gas does not. What matters is that the fuel decision is made early, because it drives trenching, permits, and the pad location.
Fuel choice also decides which price you are exposed to during a long outage. Natural gas units ride the same market drivers as home heating, and PetroEyes lays out those drivers in what drives natural gas prices, while propane units depend on a tank you must keep filled and a truck that can reach you.
5. Permits, Site Work, and Placement Rules
A standby generator is a permanent, fuel-burning appliance wired into your home's electrical system. Expect permits - typically electrical, and often gas/plumbing and building as well, depending on the municipality. Permit fees in the $200-$800 range are common, but the real cost of permits is time: schedule the project with inspection lead times in mind, not just the installer's availability.
Placement rules are the part homeowners underestimate. The unit must sit a code-specified distance from the house (commonly around 5 feet from any opening such as windows and doors, and with clearances on all sides for airflow and service), away from the gas meter regulator vent by a specified distance, and with the exhaust pointed away from the house. It cannot sit under a deck or inside an enclosure that traps exhaust. Your installer should do a site survey and mark the pad location before you sign - if a contractor quotes without seeing the yard, the quote is a guess.
Site work items that commonly add cost:
- The pad: a level concrete pad or compacted gravel bed. Gravel is cheaper and fine in most jurisdictions; concrete looks better and lasts longer.
- Trenching: for the gas line and the electrical conduit between the house and the unit. Longer runs and hard digging (rock, tree roots) cost more.
- Gas meter upgrade: as discussed in section 4 - confirm with the utility early.
- Panel work: a new sub-panel, breaker space, or panel reorganization for the transfer switch.
- Landscaping repair: trenches leave scars. Budget a few hundred dollars for sod or seed if the run crosses the lawn.
- Noise: air-cooled units are about as loud as a lawn mower. Check local noise ordinances and be a good neighbor - placement near a bedroom window or a property line invites complaints. Some manufacturers offer quieter enclosures; ask.